Model: Infosec Sine Wave 800
High-performance protection
The On Line Performance technology controlled by microprocessor makes the E2 LCD an ideal protection solution thanks to its perfect sinusoidal current and fully protected outlput. It also provides effective protection for particularly sensitive loads such as servers or even video surveillance, telephone switchboards, VOIP etc. In the event of a power cut, E2 LCD offers up to 60 min. of backup time therefore ensuring uninterrupted service or critical data backup.
Smart features
The built-in charger takes only 4 hours to reach maximum backup capacity. When the UPS is not powered up, the cold startup function enables emergency starting of connected hardware. When power is restored the UPS automatically starts up again and does not require any operator input.
Energy saving features
The battery automatically recharges when there is mains power and the UPS is OFF. This feature, available for the whole range, ensures that when connected devices are not in use and the UPS is OFF, the battery continues recharging. Real energy savings are achieved thanks to its advanced battery charger which enables the batteries to charge twice as fast as normal.
Designed for ease of use
• A single On/Off switch
• LCD screen and audible alarms indicating UPS status
Specifications
- Technology: On Line Performance controlled by microprocessor
- Power: 800 VA
- Power factor: 0.6
- IEC outputs with backup time: 4
- Tel./ADSL line protection RJ11/45 (1-IN/1-OUT)
PROTECTION & FILTERING
- Output form: Pure sinusoidal
- Protection: Discharge / overload / overvoltage + Tel./ADSL line
- Input protection: Circuit breaker
- Overvoltage protection: Phase-Neutral protection: 1 kV; Phase-Ground & Neutral-Ground protection: 2 kV
PHYSICAL CHARACTERISTICS
- Dimensions (LxWxH): 145 x 100 x 330mm
- Net weight: 6 kg
INPUT TECHNICAL CHARACTERISTICS
- Voltage: [110-120 VAC] or [220/230/240 VAC]*
- Voltage range: [81-145 VAC] or [162-290 VAC]*
- Frequency: 50/60 Hz (auto-detection)
OUTPUT TECHNICAL CHARACTERISTICS
- Voltage: [110-120 VAC] or [220/230/240 VAC]*
- Automatic voltage regulation: ± 10%
- Frequency: 50 or 60 Hz ± 1Hz
BATTERY
- Battery charger: Automatic battery charging upon connection to the mains
- Cold startup (no mains): yes
- Battery type & number: 12 V/9 Ah x 1
- Recharging time: 4-6 hours at 90% after total discharge
- Backup time: From 12 to 60 min. depending on the connected load
DISPLAY
- LCD screen: Mains power supply mode, battery mode, output charge level, battery level, input voltage, output voltage, overload, fault and battery low
AUDIBLE ALARM
- Battery mode: Sounding every 10 seconds
- Low battery mode: Sounding every second
- Overload: Sounding every half second
- Battery replacement: Sounding every 2 seconds
- Fault: Continuous sounding
COMMUNICATION
- USB communication port: Yes
- RS232 communication port: No
- Communication software: InfoPower (supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, 8, Linux, Unix et MAC)
ENVIRONMENT
- Ideal environment: 0-40°C, 0-90% relative humidity (without condensation)
- Noise level: < 40 dB
NORMS
- Standard: CE RoHS
- Electromagnetic compatibility: EN 62040-2 / IEC 61000-4-2 / IEC 61000-4-3 / IEC 61000-4-4 / IEC 61000-4-5 / IEC 61000-2-2
- Low voltage safety: EN 62040-1-1 / IEC 60950-1
SALES INFO
* Low voltage (110V) and High voltage (230V) are different products