Model: Teltonika TRB145
INDUSTRIAL RUGGED LTE RS485 GATEWAY
Features
- TRB145 is a mission-critical LTE Cat 1 gateway, equipped with RS485 interface.
Â
- Compact design and easy installation make this gateway perfect for applications, where a sole gadget must be remotely controlled over the RS485 serial interface.
Â
- Just like the rest of TRB products, TRB145 is engineered to be used in industrial applications. Therefore, it has a wide range of software features, such as SMS control,
Firewall, Open VPN, IPsec, Teltonika Networks Remote Management System (RMS), and FOTA support.
Specifications
MOBILE
- Mobile module: 4G (LTE) – Cat 1 up to 10 Mbps, 3G – Up to 42 Mbps, 2G – Up to 236.8 kbps
- Bridge: Direct connection (bridge) between mobile ISP and device on LAN
- Status: Signal strength (RSSI), SINR, RSRP, RSRQ, EC/IO, RSCP Bytes sent/received
- SMS/Call: SMS status, SMS configuration, Call utilities
NETWORK
- Network protocols: TCP, UDP, IPv4, IPv6, ICMP, NTP, DNS, HTTP, HTTPS, SSL v3, TLS, PPP, SSH, DHCP, SNMP, MQTT
- Connection monitoring: Ping Reboot, Periodic Reboot, LCP and ICMP for link inspection, Wget
- Routing: Static routing
- Firewall: Port forwards, traffic rules, custom rules
- DHCP: Static and dynamic IP allocation
- QoS / Smart Queue Management (SQM) (planned): Traffic priority queuing by source/destination, service, protocol or port
- DDNS: Supported >25 service providers, others can be configured manually
SECURITY
- Authentication: Pre-shared key, digital certificates, X.509 certificates
- Firewall: Pre-configured firewall rules can be enabled via the WebUI, unlimited firewall configuration via CLI; NAT; NAT-T
- Access control: Flexible access control of TCP, UDP, ICMP packets, MAC address filter
VPN
- OpenVPN: Multiple clients and a server can run simultaneously, 12 encryption methods
- OpenVPN Encryption: DES-CBC, RC2-CBC, DES-EDE-CBC, DES-EDE3-CBC, DESX-CBC, BF-CBC, RC2-40-CBC, CAST5-CBC, RC2-64-CBC, AES-128-CBC, AES-192-CBC, AES-256-CBC
- IPsec: IKEv1, IKEv2, supports up to 5 x VPN IPsec tunnels (instances), with 5 encryption methods (DES, 3DES, AES128, AES192, AES256)
- GRE: GRE tunnel
- PPTP, L2TP: Client/Server services can run simultaneously
SERIAL COMMUNICATION MODES
- Modes: Console, OverIP, Modem (Full or Partial control) (planned), Modbus RTU master, Modbus gateway, NTRIP client (planned)
MODBUS
MODBUS TCP SLAVE
- ID filtering: Respond to one ID in range [1;255] or any
- Allow remote access: Allow access through WAN
- Custom registers: Modbus TCP custom register block, which allows to read/write to a file inside the router, and can be used to extend Modbus TCP slave functionality
MODBUS TCP MASTER
- Supported functions: 01, 02, 03, 04, 05, 06, 15, 16
- Supported data formats: 8 bit: INT, UINT; 16 bit: INT, UINT (MSB or LSB first); 32 bit: float, INT, UINT (ABCD (big-endian), DCBA (little-endian), CDAB, BADC)
MODBUS RTU MASTER
- Supported baud rates: From 300 to 115200
- Supported functions: 01, 02, 03, 04, 05, 06, 15, 16
- Supported data formats: 8 bit: INT, UINT; 16 bit: INT, UINT (MSB or LSB first); 32 bit: float, INT, UINT (ABCD (big-endian), DCBA (little-endian), CDAB, BADC)
- Number of data bits: From 5 to 8
- Number of stop bits: 1 or 2
- Parity: None, Even, Odd
- Flow control: None, Xon/Xoff
MODBUS DATA TO SERVER
MONITORING & MANAGEMENT
- WEB UI: HTTP/HTTPS, status, configuration, FW update, CLI, troubleshoot, system log, kernel log
- FOTA: Firmware update from sever, automatic notification
- SSH: SSH (v1, v2)
- SMS: SMS status, SMS configuration
- MQTT: MQTT Broker, MQTT publisher
- JSON-RPC: Management API over HTTP/HTTPS
- Modbus: Modbus TCP status/control
- RMS: Teltonika Remote Management System (RMS)
SYSTEM CHARACTERISTICS
- CPU: ARM Cortex-A7 1.2 GHz CPU
- RAM: 128 MB (50 MB available for userspace)
- FLASH memory: 512 MB (200 MB available for userspace)
FIRMWARE / CONFIGURATION
- WEB UI: Update FW from file, check FW on server, configuration profiles, configuration backup
- FOTA: Update FW/configuration from server
- RMS: Update FW/configuration for multiple devices
- Keep settings: Update FW without losing current configuration
FIRMWARE CUSTOMIZATION
- Operating system: RutOS (OpenWrt based Linux OS)
- Supported languages: Busybox shell, Lua, C, C++
- Development tools: SDK package with build environment provided
INPUT/OUTPUT
- Configurable I/O: 2 x Digital Inputs/Outputs (I/O not available in TRB145*2****)
- Events: SMS status
POWER
- Connector: 4 pin industrial DC power socket
- Input voltage range: 9 – 30 VDC (4 pin industrial socket), reverse polarity protection, surge protection >33 VDC 10? max
- Power consumption: < 5 W
PHYSICAL INTERFACES (PORTS, LEDS, ANNTENAS, BUTTONS, SIM)
- RS485: RS485 interface, Full Duplex (4 wires) and Half Duplex (2 wires), baud rate 300-115200
- I/Os: 2 Inputs/Outputs pin on 4 pin power connector (I/O not available in TRB145*2****)
- USB: Virtual network interface via USB
- Status LEDs: 3 x connection type status LEDs, 5 x connection strength LEDs, 1x Power LED
- SIM: 1 x SIM slot (Mini SIM – 2FF), 1.8 V/3 V
- Power: 4 pin power connector with 2 x configurable Digital Inputs/Outputs (I/O not available in TRB145*2****)
- Anntenas: 1 x SMA for LTE
- Reset: Restore factory settings button
PHYSICAL SPECIFICATIONS
- Casing material: Aluminum housing
- Dimensions: 64.4 x 74.5 x 25 mm (L x W x H)
- Weight: 130 g
- Mounting options: Bottom and sideways DIN rail, Flat surface and direct PCB on DIN-Rail mounting options
OPERATING ENVIRONMENT
- Operating temperature: -40 °C to 75 °C
- Operating humidity: 10 % to 90 % non-condensing
- Ingress Protection Rating: IP30
REGULATORY & TYPE APPROVALS
- Regulatory: CE/RED, EAC, RoHS, WEEE
EMI
- Standards: Draft ETSI EN 301 489-1 V2.2.0, Draft EN 301 489-19 V2.1.0, Draft ETSI EN 301 489-52 V1.1.0
- ESD: EN 61000-4-2:2009
- RS: EN 61000-4-3:2006 + A1:2008 + A2:2010
- EFT: EN 61000-4-4:2012
- Surge protection: EN 61000-4-5:2014
- CS: EN 61000-4-6:2014
- DIP: EN 61000-4-11:2004
RF
- Standards: EN 300 511 V12.5.1, ETSI EN 301 908-1 V11.1.1, ETSI EN 301 908-2 V11.1.2, ETSI EN 301 908-13 V11.1.2
SAFETY
- Standards:
- IEC 62368-1:2014(Second Edition), EN 62368-1:2014+A11:2017
- EN 50385:2017
- EN 62232:2017