PLANET IP30 INDUSTRIAL SOLAR POWER POE SWITCH 4-PORT GIGABIT PLANET IP30 INDUSTRIAL SOLAR POWER POE SWITCH 4-PORT GIGABIT PLANET IP30 INDUSTRIAL SOLAR POWER POE SWITCH 4-PORT GIGABIT PLANET IP30 INDUSTRIAL SOLAR POWER POE SWITCH 4-PORT GIGABIT PLANET IP30 INDUSTRIAL SOLAR POWER POE SWITCH 4-PORT GIGABIT PLANET IP30 INDUSTRIAL SOLAR POWER POE SWITCH 4-PORT GIGABIT PLANET IP30 INDUSTRIAL SOLAR POWER POE SWITCH 4-PORT GIGABIT PLANET IP30 INDUSTRIAL SOLAR POWER POE SWITCH 4-PORT GIGABIT
 
PLANET IP30 INDUSTRIAL SOLAR POWER POE SWITCH 4-PORT GIGABIT

We are sorry, this product is not available anymore
Show full specificationsHide full specifications

PRODUCT FEATURES

Physical Port

  • 5-port 10/100/1000BASE-T Gigabit RJ45 copper with 4-port IEEE 802.3at/af PoE Injector (Port 1 to Port 4)
  • RJ45 type interface for basic management and setup
  • USB type A female for setting file backup and restore

Power over Ethernet

  • Complies with IEEE 802.3at Power over Ethernet Plus end-span PSE
  • Backward compatible with IEEE 802.3af Power over Ethernet
  • Up to 4 ports of IEEE 802.3af/802.3at devices powered
  • Supports PoE power up to 30 watts for each PoE port
  • Auto detects powered device (PD)
  • Circuit protection prevents power interference between ports
  • Remote power feeding up to 100 meters
  • PoE management:
      • Total PoE power budget control
      • Per port PoE function enable/disable
      • PoE port power feeding priority
      • Per PoE port power limitation
      • PD alive-check
      • PoE schedule

Battery Management

  • Battery type option: Nickel-cadmium battery or lead-acid battery
  • Easy diagnostic of the system operating status via LED indicator
  • Battery current usage and status
  • Battery capacity and power consumption statistics
  • Low voltage cut-off protection: Send alert and cut off the low priority PoE port for the low power battery
  • Pulse Width Modulation (PWM) Protection:
      • Reverse current protection to prevent the current circuits from flowing back to the PV panel
      • Over-current and over-temperature protection
      • Reverse polarity protection (for battery and charging electrodes)

Industrial Case & Installation

  • IP30 aluminum case
  • DIN-rail and wall-mounted design
  • Supports -10 to 60 degrees C operating temperature
  • Supports ESD 6KV DC Ethernet protection
  • Redundant power design:
      • 48V~56V DC wide power input

Switching

  • Hardware based 10/100Mbps (half/full duplex), 1000Mbps (full duplex), auto-negotiation and auto MDI/MDI-X
  • Features Store-and-Forward mode with wire-speed filtering and forwarding rates
  • IEEE 802.3x flow control for full duplex operation and back pressure for half duplex operation
  • 8K MAC address table size
  • Automatic address learning and address aging

Router

  • Internet types: Dynamic IP, static IP, PPPoE, L2TP, PPTP
  • Static and dynamic (RIP1 and 2) routing
  • IP/MAC-based bandwidth control
  • Supports Port Forwarding, DMZ, UPnP and Dynamic DNS for various networking applications
  • 802.1d STP and  IGMP Proxy

 

Security

  • Port filtering lets you either allow or prevent which applications can access the Internet.
  • MAC filtering allows you to include or exclude computers and devices based on their MAC address
  • URL filtering allows you to control access to Internet websites in an URL list
  • IP source guard prevents IP spoofing attacks
  • DoS attack prevention

Management

  • Switch Management Interface
      • IPv4 Web switch management
      • SNMP v1, v2c
  • Static and DHCP for IP address assignment
  • System Maintenance
      • Firmware upload/download via HTTP
      • Configuration upload/download through HTTP
      • Hardware reset button for system reboot or reset to factory default
  • NTP Network Time Protocol
  • SNMP trap for interface Link Up and Link Down notification
  • Event message logging to remote syslog server
  • PLANET Smart Discovery Utility

PRODUCT SPECIFICATIONS

Main Components

  • Web Server Controller: Realtek 8198 x 1
  • CPU: RLX5281/500MHz x 1
  • Flash: 4MBytes x 1
  • SDRAM: 64Mbytes x 1
  • PoE Chip: PD69104B x 1

Hardware Specifications

  • Copper Ports:
      • LAN: 5 10/100/1000Mbps auto MDI/MDI-X RJ45 port (Port 1 to Port 5, bridge mode)
      • WAN: 1 10/100/1000Mbps auto MDI/MDI-X RJ45 port (Port 5, gateway mode)
  • PoE Injector Port:
      • 4 ports with 802.3af/802.3at PoE injector function (Port 1 to Port 4)
  • USB:
      • 1 USB Type A female for setting backup
  • Power Output:
      • 4 PoE out 51VDC; max. 30 watts per PoE port
      • 2 DC out 24@ 1A maximum (four-pin terminal block)
      • The voltage of DC out is based on the battery.
  • Switch Architecture: 
      • Store-and-Forward
  • Switch Fabric: 
      • 10Gbps/non-blocking
  • Switch Throughput@64 bytes: 
      • 5.95Mpps@64 bytes
  • MAC Address Table: 
      • 8K entries
  • Shared Data Buffer: 
      • 512Kbit
  • Flow Control: 
      • IEEE 802.3x pause frame for full-duplex
      • Back pressure for half-duplex
  • Reset Button:
      • < 5 sec: System reboot
      • > 5 sec: Factory default
  • LED:
    • 3 LEDs for System and Power:
      • Green: Power
      • Green: Fault
      • Green: System
    • 4 LEDs for PoE Copper Ports (Port 1~Port 4):
      • Green: LNK/ACT
      • Orange: PoE-in-use
    • 1 LED for 10/100/1000T Copper Port (Port 5):
      • Green: LNK/AC
    • 3 LEDs for PoE Power Usage (W)
      • Green: 50, 100 and 120W
  • Connector:
      • Removable 6-pin terminal block
      • Pin 1/2 for PV panel; Pin 3/4 for alarm; Pin 5/6 for battery
  • Alarm:
      • 1 Digital Output (DO):
      • Level 0: -24V~2.1V (±0.1V)
      • Level 1: 2.1V~24V (±0.1V)
      • Open collector to 24V DC, 100mA max.
  • Power Requirements:
      • PV in: 24~45V DC
      • Battery in/out: 24V DC
  • Power Consumption/ Dissipation:
      • 5.04 watts, 17.1BTU (Standby without PoE function)
      • 6.96 watts, 23.7 BTU (Full loading without PoE function)
      • 135.36 watts, 461.5 BTU (Full loading with PoE function)
  • Dimensions (W x D x H): 
      • 84 x 107 x 152 mm
  • Weight: 
      • 1026g
  • ESD Protection: 
      • 6KV DC
  • Enclosure: 
      • IP30 aluminum case
  • Installation: 
      • DIN-rail kit and wall-mount ear

Power over Ethernet

  • PoE Standard: 
      • IEEE 802.3af/802.3at Power over Ethernet PSE
  • PoE Power Supply Type: 
      • End-span
  • PoE Power Output:
      • Per port 51V DC, 275mA. Max. 15.4 watts (IEEE 802.3af)
      • Per port 51V DC, 535mA. Max. 30 watts (IEEE 802.3at)
  • Power Pin Assignment: 
      • 1/2 (+), 3/6 (-)
  • PoE Power Budget: 
      • 120 watts (PoE consumption + DC out and depending on power input)
  • Max. Number of Class 2 PDs: 
      • 4
  • Max. Number of Class 3 PDs: 
      • 4
  • Max. Number of Class 4 PDs: 
      • 4

Electrical Characteristics

  • System Voltage Rating: 
      • 24V DC
  • Maximum Charging Current: 
      • 6A
  • Max. Solar Array VOC: 
      • 60V DC
  • Max. Operating Voltage:  
      • 45V DC
  • Total Current Consumption:
      • While operating -32mA
      • At idle -11mA
  • High Temperature Shutdown:
      • 100 degrees C disconnect solar and load
      • 80 degrees C reconnect solar and load

Battery Charging Characteristics

  • Charge Algorithm:
      • Bulk charge (constant current), Absorption charge (constant voltage) and Floating charge. Absorption and Floating charge with PWM protection.
  • Maximum Output Current: 
      • 6A
  • Nickel-cadmium Battery:
      • ± 40 mV/degrees Celsius for NiCad type batteries; charge cut-off @ 55 degrees C
      • (Temperature compensation baseline@ 25 degrees C)
  • Lead Acid Battery (Default Setting):
      • ± 60 mV/degrees Celsius for lead acid type batteries; charge cut-off @ 55 degrees C(Temperature compensation baseline@ 25 degrees C)
  • Float Charge Voltage: 
      • DC 27.2V (26.0~30.0V)
  • Absorption Charge Voltage: 
      • DC 29.2V (28.0~32.0V)
  • LVD (Low Voltage Disconnection): 
      • DC 22.2V (21.0~25.0V)
  • LVR (Low Voltage Reconnection): 
      • DC 24.8V (23.0~27.0V)

Router Features

  • Internet Connection Type: 
    • Shares data and Internet access with users, supporting the following internet accesses:
      • PPPoE
      • Dynamic IP
      • Static IP
      • PPTP
      • L2TP
  • Firewall:

      • NAT firewall with SPI (Stateful Packet Inspection)
      • Built-in NAT server supporting Port Forwarding, and DMZ
      • Built-in firewall with IP address/MAC address/Port/ URL filtering
      • Supports ICMP-FLOOD, UDP-FLOOD, TCP-SYN-FLOOD filter, DoS protection
  • Routing Protocol: 
      • Static/Dynamic (RIP1 and 2) routing
  • VPN Pass-through: 
      • PPTP, L2TP, IPSec, IPv6
  • LAN: 
      • Built-in DHCP server supporting static IP address distribution
      • Supports UPnP, Dynamic DNS
      • Supports IGMP Proxy
      • Supports 802.1d STP (Spanning Tree)
      • IP/MAC-based bandwidth control

Management

  • Management Interface:
      • Setup of system/management functions
      • Web firmware upgrade
      • SNMP trap for alarm notification of events
  • PoE Management:
      • Power limit by consumption and allocation
      • PoE admin mode
      • Per port power schedule
      • Per port power enable/disable
      • Power feeding priority
      • Current per port usage and status
      • Total power consumption
      • PD alive check
      • Scheduled power recycling
  • Battery Management: 
      • Battery current usage and status
      • Battery capacity statistics
      • Low Voltage Cut-Off Protection

Standards Conformance

  • Regulatory Compliance:
      • FCC Part 15 Class A, CE
  • Standards Compliance:
      • IEEE 802.3 10BASE-T Ethernet
      • IEEE 802.3u 100BASE-TX Fast Ethernet
      • IEEE 802.3ab 1000BASE-T Gigabit Ethernet
      • IEEE 802.3x Flow Control and Back Pressure
      • IEEE 802.1D Spanning Tree Protocol
      • IEEE 802.3af Power over Ethernet
      • IEEE 802.3at Power over Ethernet Plus
      • RFC 768: UDP
      • RFC 791: IP
      • RFC 2068 HTTP
      • RFC 1157: SNMP v1
      • RFC 1902: SNMP v2c
      • RFC 5424: Syslog

Environment

  • Operating:
      • Temperature: -10 ~ 60 degrees C
      • Relative Humidity: 5 ~ 95% (non-condensing)
  • Storage:
      • Temperature: -10 ~ 70 degrees C
      • Relative Humidity: 5 ~ 95% (non-condensing)