Components: Power supply: DIN-RAIL 24V/10A, 240W POWER SUPPLY
DIN-RAIL 24V/10A, 240W POWER SUPPLY
 
DIN-RAIL 24V/10A, 240W POWER SUPPLY
147,10-incl. VAT

Order before 2 pm, delivered at home tomorrow
Order before 2 pm, pick up in store from tomorrow

EAN: 5420016882004
MPN: DRL-24V240W1EN
Brand: Noname
Stock: 1

Show full specificationsHide full specifications

Model: OEM DRL-24V240W1EN

Features

  • Universal AC input voltage range
  • Built-in constant current circuit for reactive loads
  • High power density
  • Operate from -30°C to +70°C with -40°C Cold Start
  • Reduced no-load power consumption
  • Compliance with DOE VI Energy Standard
  • Compliance to SEMI F47 @ 200Vac

Specifications

INPUT

  • Input Voltage: 100-240Vac
  • Input Voltage Range: 90-264Vac
  • Nominal Input Frequency: 50-60Hz
  • Input Frequency Range: 47-63Hz
  • Input Current: 2.5A typ. @ 115Vac, 1.3A typ. @ 230Vac
  • Efficiency at 100% load: 90.0% typ. @ 230Vac
  • Max Inrush Current: 40A typ. @ 230Vac
  • Power Factor at 100% load: > 0.95 @ 115Vac & 230Vac
  • Leakage Current: < 0.75mA @ 240Vac

MECHANICAL

  • Case Chassis / Cover: Aluminum / SGCC
  • Indicator: Green LED (DC OK)
  • Cooling System: Convection
  • Input Terminal: 3 Pins (Rated 300V/30A)
  • Output Terminal: 4 Pins (Rated 300V/20A)
  • Noise Sound Pressure Level (SPL): < 25dBA
  • Mounting Rail: Standard TS35 DIN Rail in accordance with EN 60715
  • Unit Weight: 0.62 kg (1.37 lb)
  • Dimensions: 
    • 123.6 x 40 x 117.2 mm
    • 4.87” x 1.57” x 4.61”

ENVIRONMENT

  • Vibration (Operating): IEC 60068-2-6, Sine Wave: 10Hz to 500Hz @ 19.6 m/s² (2G peak); 10 min per cycle, 60 min for X direction
  • Shock Test (Operating): IEC 60068-2-27, Half Sine Wave: 10G for duration of 11ms; 1 time in X axis
  • Operating Temperature: -30°C to +70°C (-40°C Cold Start)
  • Storage Temperature: -40°C to +85°C
  • Power De-rating: 
    • > 40°C de-rate power by 1.67 % / °C @115Vac
    • > 50°C de-rate power by 2.5 % / °C @230Vac
  • Operating Humidity: 20 to 90% RH (Non-Condensing)
  • Shock Test (Non-Operating): IEC 60068-2-27, Half Sine Wave: 50G for duration of 11ms; 3 times per direction, 9 times in total
  • Vibration (Non-Operating): IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 20 min per axis for all X, Y, Z direction
  • Operating Altitude: 0 to 5,000 Meters (16,400 ft.)
  • Pollution Degree: 2
  • Over Voltage Category: II (Compliance to EN 62477-1 OVC III with 2000 meters altitude)

PROTECTIONS

  • Overvoltage: <33.6V, SELV Output, Latch Mode
  • Overload / Overcurrent:
    • 105 - 150% of rated load current, Auto-recovery
    • Continuous current limit Mode (Vo>80%)
  • Over Temperature: Latch Mode
  • Short Circuit: Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
  • Protection Against Shock: Class I with Primary Earth connection

RELIABILLITY

  • MTBF: 
  • > 700,000 hrs. as per Telcordia SR-332
  • I/P: 115Vac & 230Vac, O/P: 100% load, Ta: 25°C
  • Expected Cap Life Time: 10 years (230Vac, 50% load @ 40°C)

SAFETY

  • Electrical Safety:
    • CB scheme : IEC 62368-1, IEC 60950-1, IEC 61010-1 & -2-201
    • TUV Bauart : EN 62368-1, EN 61010-1 & -2-201
    • UL/cUL : UL 62368-1
    • CCC : GB4943.1
    • EAC : TP TC 004/2011
    • KC : K60950-1 (24V model only)
  • CE: In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU

Order before 2 pm = delivered at home tomorrow or pick up in store from tomorrow*
*: the delivery times are indications & depend on suppliers and transport companies

147.10 Free shipping from € 50