DIN-RAIL 24V/10A, 240W POWER SUPPLY
Order before 2 pm, delivered at home tomorrow
Order before 2 pm, pick up in store from tomorrow
EAN: 5420016882004
MPN: DRL-24V240W1EN
Brand: Noname
Stock: 1
Show full specificationsHide full specificationsModel: OEM DRL-24V240W1EN
Features
- Universal AC input voltage range
- Built-in constant current circuit for reactive loads
- High power density
- Operate from -30°C to +70°C with -40°C Cold Start
- Reduced no-load power consumption
- Compliance with DOE VI Energy Standard
- Compliance to SEMI F47 @ 200Vac
Specifications
INPUT
- Input Voltage: 100-240Vac
- Input Voltage Range: 90-264Vac
- Nominal Input Frequency: 50-60Hz
- Input Frequency Range: 47-63Hz
- Input Current: 2.5A typ. @ 115Vac, 1.3A typ. @ 230Vac
- Efficiency at 100% load: 90.0% typ. @ 230Vac
- Max Inrush Current: 40A typ. @ 230Vac
- Power Factor at 100% load: > 0.95 @ 115Vac & 230Vac
- Leakage Current: < 0.75mA @ 240Vac
MECHANICAL
- Case Chassis / Cover: Aluminum / SGCC
- Indicator: Green LED (DC OK)
- Cooling System: Convection
- Input Terminal: 3 Pins (Rated 300V/30A)
- Output Terminal: 4 Pins (Rated 300V/20A)
- Noise Sound Pressure Level (SPL): < 25dBA
- Mounting Rail: Standard TS35 DIN Rail in accordance with EN 60715
- Unit Weight: 0.62 kg (1.37 lb)
- Dimensions:
- 123.6 x 40 x 117.2 mm
- 4.87” x 1.57” x 4.61”
ENVIRONMENT
- Vibration (Operating): IEC 60068-2-6, Sine Wave: 10Hz to 500Hz @ 19.6 m/s² (2G peak); 10 min per cycle, 60 min for X direction
- Shock Test (Operating): IEC 60068-2-27, Half Sine Wave: 10G for duration of 11ms; 1 time in X axis
- Operating Temperature: -30°C to +70°C (-40°C Cold Start)
- Storage Temperature: -40°C to +85°C
- Power De-rating:
- > 40°C de-rate power by 1.67 % / °C @115Vac
- > 50°C de-rate power by 2.5 % / °C @230Vac
- Operating Humidity: 20 to 90% RH (Non-Condensing)
- Shock Test (Non-Operating): IEC 60068-2-27, Half Sine Wave: 50G for duration of 11ms; 3 times per direction, 9 times in total
- Vibration (Non-Operating): IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 20 min per axis for all X, Y, Z direction
- Operating Altitude: 0 to 5,000 Meters (16,400 ft.)
- Pollution Degree: 2
- Over Voltage Category: II (Compliance to EN 62477-1 OVC III with 2000 meters altitude)
PROTECTIONS
- Overvoltage: <33.6V, SELV Output, Latch Mode
- Overload / Overcurrent:
- 105 - 150% of rated load current, Auto-recovery
- Continuous current limit Mode (Vo>80%)
- Over Temperature: Latch Mode
- Short Circuit: Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
- Protection Against Shock: Class I with Primary Earth connection
RELIABILLITY
- MTBF:
- > 700,000 hrs. as per Telcordia SR-332
- I/P: 115Vac & 230Vac, O/P: 100% load, Ta: 25°C
- Expected Cap Life Time: 10 years (230Vac, 50% load @ 40°C)
SAFETY
- Electrical Safety:
- CB scheme : IEC 62368-1, IEC 60950-1, IEC 61010-1 & -2-201
- TUV Bauart : EN 62368-1, EN 61010-1 & -2-201
- UL/cUL : UL 62368-1
- CCC : GB4943.1
- EAC : TP TC 004/2011
- KC : K60950-1 (24V model only)
- CE: In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
Order before 2 pm = delivered at home tomorrow or pick up in store from tomorrow*
*: the delivery times are indications & depend on suppliers and transport companies € 147.10